.jpg)

.jpg)
.jpg)

.jpg)
It receives synchronization logic, relay output contacts, drives the generator grid-connected circuit breaker closing circuit, and performs protection actions such as reverse power, overcurrent, overvoltage, and undervoltage. It outputs hard contacts to trigger circuit breaker tripping, unit shutdown, and switch hard contacts for unit operation, readiness, and fault status. It interfaces with the ship's PMS power management system.
Note that all products on this website are special products, and market prices are constantly fluctuating.
Please refer to customer service for a quote, as the price may not be accurate as the product is new.
Please confirm the model, product, price, and other detailed information with customer service before placing an order. This website is currently in use.
New products are available for sale; please contact customer service for further information.
I.
Core Functions
This board is an internal slot-type relay output board for the controller. It does not perform measurements or logic operations; it only executes commands issued by the main control unit and outputs passive dry contacts.
Synchronous Closing Output: Receives synchronization logic, relay output contacts, and drives the generator grid-connected circuit breaker closing circuit.
Protection Trip Output: Outputs hard contacts for reverse power, overcurrent, overvoltage, undervoltage, and other protection actions, triggering circuit breaker tripping and unit shutdown.

Alarm Signal Output: Fault and warning status relay outputs, connecting to the engine room alarm system, alarm indicator lights, and external alarm relays.
Unit Status Output: Hard contacts for unit operation, readiness, and fault status, connecting to the ship's PMS power management system. Internal Bus Interaction: The backplane socket connects to the PPU-2 internal bus, receiving logic levels from the main control board to drive the onboard relay coils.
II.
Application Scenarios
Marine Power Stations: Parallel protection and control of multiple diesel generators, ship main switchboard, and emergency power station control systems.
Land-based Backup Power Stations: Complete systems using the Multi-Line2 platform PPU-2 controller in industrial plants with multiple generator units in parallel or isolated grid operation.
Supporting Equipment: Works with the PMS power management system to complete parallel operation, protection tripping, and status hard signal interaction.
III.
Usage and Maintenance Precautions
Hardware Compatibility
Only the designated slots on the chassis can be used; other series boards cannot be used interchangeably.
Relay Load Limits
Relay resistive loads are limited to a maximum of 8A, UL certified 2A; inductive loads (contactors, coils) must have an RC surge absorption circuit added to prevent contact arcing.
Do not drive high-power loads with excessive current; otherwise, the relay will be quickly damaged.

Marine Environmental Protection
In high humidity and salt spray environments, focus on inspecting the backplane gold fingers to prevent oxidation and corrosion; disconnect power before disassembly and reassembly. The gold fingers can be cleaned with anhydrous alcohol.
Maintain ventilation inside the chassis to prevent condensation from causing leakage and short circuits on the circuit boards.
Disassembly and Repair Points
Completely power off the entire unit before inserting or removing circuit boards. Hot-swapping is strictly prohibited to prevent damage to the backplane bus.
Fault Diagnosis: When the controller issues an action command, measure whether the relay coil is energized; if the coil is energized but the contacts are not continuous, the circuit board is confirmed to be damaged.
.jpg)
Do not replace the relays on the board yourself; matching parameters are critical, and repairs will reduce reliability.
Fault Differentiation
External wiring and external relay faults can also cause invalid outputs. Do not directly conclude that the circuit board is damaged; first check the external circuitry.
Recommended
related products:
DEIF
SCM-1
DEIF
GC-1F/2
DEIF
GPU-2-GS
WSS-L
DEIF
DIM5.1
DEIF
PPM
BTB DEIF
AGC/GS/2
DEIF
CP-1
DEIF
TAP-210DG/1
DEIF
DPD 04057
DEIF
OPM-1
DEIF
AGC
3X DEIF
PCM4-1
PCM4-3
PCM5-2
PCM4-4
BRW-2
200-0-200 DEIF
IMD
122A DEIF
IMD
100 DEIF
DGU 4
DEIF
AWC
400 DEIF
DEIF
DGU 0003
More......
.jpg)





.jpg)



.jpg)
Address
Room 205, Office Building, No.1 Chaoyang North Road, Longwen District, Zhangzhou City, Fujian Province
fengyunfadacai@qq.com
Sales consultant
Miss.Green
+86 15860249102
