The module is a 9U high printed circuit board with an integral front panel and front and rear connectors; a plug-in daughter board with RS232 interface circuit. All input/output modules have two mechanical coding blocks with pins that can be matched with the holes on the corresponding module blocks in the chassis to prevent the module from being inserted into the wrong slot. The pins on the module blocks are installed in the pattern determined by the module before leaving the factory, and the unused holes are blocked with fixing screws.
Many products have not been put on the shelves yet, please contact us for more products
If the product model is inconsistent with the display picture, the model shall prevail. Please contact us for specific product pictures, and we will arrange to take photos in the warehouse for confirmation
We have 76 shared warehouses around the world, so sometimes it may take several hours to return to you accurately, please understand. Of course, we will respond to your concerns as soon as possible.
3BHL000986P7002 Other names:
Input and output module 3BHL000986P7002
3BHL000986P7002 controller module
Analog module 3BHL000986P7002
Basic features
Appearance and structure: The module is a 9U high printed circuit board with an integral front panel and front and rear connectors; a plug-in daughter board with RS232 interface circuit. All input/output modules are equipped with two mechanical encoding blocks with pins that can be matched with the holes on the corresponding module blocks in the chassis to prevent the module from being inserted into the wrong slot. The pins on the module blocks are installed according to the module-determined pattern before leaving the factory, and the unused holes are blocked with fixing screws.
Installation location: In the system, a serial communication module must be used and installed in slot 10 to support communication between system processors and between host and workstation.
Module structure: It is a 9U high printed circuit board with an integral front panel and front and rear connectors; a plug-in daughter board with RS232 interface circuit. All input/output modules are equipped with two mechanical coding blocks equipped with pins that can be matched with the holes on the corresponding module blocks in the chassis to prevent the module from being inserted into the wrong slot.
Link configuration: There are three links LK2, LK3 and LK4 on the lower part of the PCB. LK2 (2 pins) is located about 220 mm below the top of the module and 110 mm inward from the front. It is used for voltage monitoring circuits and is always installed; LK3 (3 pins) is located below the plug-in daughter board for 3-2-1 or 3-2-0 operation. It is hard-wired at the factory and all pins are connected for 3-2-1 mode; LK4 (3 pins) is located about 250 mm below the top of the module and 220 mm from the front. It is used to set the daughter board clock speed. Pins 1 and 2 are connected.
Function
Application
Serial communication: Provides multiple RS232 serial ports to support communication with various serial devices. It can connect serial devices such as PLC, inverter, and sensor to achieve automatic control.
Data transmission: Realizes data exchange between SC300E system and external devices, used to collect operating data of various devices and transmit them to the host computer.
Remote monitoring: Can be used to monitor and control remote devices.
Fault diagnosis: With fault diagnosis function, problems can be quickly located and solved.
System support: A serial communication module must be used in the system and installed in slot 10 to support communication between system processors and between host and workstation. Its main functions include loading application software, monitoring ladder diagrams and performing diagnostics, which are mainly implemented through port 0 of the module. In addition, the module also has additional modules that can be applied to any other I/O slots and prevent "wrong slotting" through mechanical coding blocks.
Technical
parameters
Isolation and power supply: The communication port is isolated from the module circuit by an optical isolator and connected to the field connector J2 at the rear of the module. These ports can power modems or line drivers for long-distance transmission. The power supply for the module circuit comes from the dual redundant SC300E power supply unit, independent circuits and regulation circuits that power different logic areas, and independent power supplies for the communication port optical isolator and interface.
Communication interface: Communication serial RS232, Intel family microcontroller.
Communication port: Port 0, Port 1, Port 2, Port 3 are all RS232 interfaces, and the baud rate can be set to 9600 or 19200. Ports 2 and 3 must be set to the same baud rate. The isolation voltage of ports 0 to 3 is 1kV. There is also a fifth port dedicated to diagnostic purposes.
Indicators: There are indicators such as Tx, Rx, Health, 3 x Online, etc.
Hot repair program: Support single-slot hot repair.
Module power consumption: 3.5W.
Total size: 400(9U)H x 397L L x 28W W (mm), 15.75H x 15.63L L x 1.1W W (inches).
Weight: 1.3kg.
Design
advantages
High reliability: Adopt industrial-grade design, suitable for harsh industrial environments.
Flexible configuration: various parameters can be configured by software to adapt to different application requirements.
Easy to install: modular design, easy to install.
Circuit protection: circuit triplicate and voting procedures make the module single fault tolerant, front panel indicators can display Tx/Rx activity, circuit online status and module health. The communication ports are isolated from the module circuit by optical isolators and connected to the field connector J2 on the rear of the module. These ports can power modems or line drivers for long-distance transmission. The power supply of the module circuit comes from the dual redundant SC300E power supply unit, independent auction and regulation circuits that power different logic areas, and the communication port optical isolator and interface also have independent power supplies.
All products on this website are special
products, and the market price has been fluctuating.
The specific price is subject to the customer service quotation, because the product is a new product, the price is not real,
Please confirm the model and product, price and other details with the customer service before placing an order. The website has been used.
New ones are on sale, please contact customer service for communication.
Related
product recommendations:
NSSM01
NAIO-03
NAMU-01C
64702475D
3BSE017427R1
NBIO-21CU
3BSE011337R1
NBIO-31
NDBU-95C
64008366D
NDCU-12C
3AUA0000052751
NDCU-33CX
3BHE028915R0101
PCD237A101
3BHE042816R0101
PCD244A101
3BHE041343R0102
PCD530A102
PVS980-58-2091kVA-L
PVS980-58-2000kVA-K
PVS980-58-1909kVA-J
PVS980-58-1818kVA-I
PPD103B103
PPD512A10-150000
PPD512A10
3BHE040375R103E
3BHE039724R0C3D
3BHE041576R3011
GFD563A102
3BHE046836R0102
GF
D563 3BHE046836R0101
PPE091A101
3BUR001401R1
PU512V2
PU515A
PU515A
3BSE032401R1
More...
Address
Room 205, Office Building, No.1 Chaoyang North Road, Longwen District, Zhangzhou City, Fujian Province
fengyunfadacai@qq.com
Sales consultant
Miss.Green
+86 15860249102